Mining Incidents

Rhoades Branch H-4 Coal

Consol Of Kentucky Inc · Underground
Controlled by CONSOL Energy Inc
Deane, Letcher County, KY  ·  Abandoned and Sealed
MSHA Mine ID: 1518212

Watch this mine

Email me when a new MSHA incident is filed at Rhoades Branch H-4.

Fatalities
0
Total incidents
25
Years on record
2000–2002
Latest incident
May 2002
Compliance record
MSHA citations since 2000
152
citations
87
significant & substantial
$25,877
proposed penalties
$25,877
paid to date
Source: MSHA violations data, updated weekly.
Quarterly safety rates
Citations per million employee-hours, as reported to MSHA
Quarter Hours worked Citations S&S Per 1M hrs
2002 Q3 672 0 0 0.0
2002 Q2 26,678 2 2 75.0
2002 Q1 41,207 17 8 412.6
2001 Q4 38,650 13 10 336.4
2001 Q3 40,208 10 7 248.7
2001 Q2 38,993 15 9 384.7
2001 Q1 40,816 39 23 955.5
2000 Q4 39,216 30 15 765.0
Quarters under 100,000 reported hours are greyed: too few hours for a stable rate.
No fatalities recorded at this mine.

Reportable incidents

25 on file

2002 · 3 incidents

May 26, 2002 KY · Coal continuous miner operator, coal mole operator HANDLING OF MATERIALS
Consol Of Kentucky Inc · Struck by falling object

EE STATED WHILE RE POSITIONING MINER CABLE LOCATED NEXT TO MINER A PIECE OF ROCK SLID OF MINER STRIKING HIM ON TOP OF HIS LEFT FOOT. EE SUSTAINED A FRACTURE TO HIS LEFT FOOT.

March 24, 2002 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

ART UNINTENTIONAL ROOF FALL OCCURRED ALONG THE PILLAR LINE IN THE #4 ENTRY AT BREAK #14. FALL WAS PART OF PILLAR FALL SIZE COULD NOT BE DETERMINED. CONTINOUS MINER WAS CAUGHT BY THE FALL, NO I NJURIES OCCURRED, VENTILATION WAS NOT INTERRUPTE

March 13, 2002 KY · Coal electrician, lineman HANDLING OF MATERIALS
Consol Of Kentucky Inc · Over-exertion (Not Elsewhere Classified)

EE STATED HE WAS CROSSING MOBILE BRIDGE WHEN HE STEPPED DOWN ON THE MINE FLOOR HE TWISTED HIS LEFT KNEE. AFTER EVALUATION BY A MEDICAL DR., IT WAS DETERMINED EE SUSTAINED A TORN LIGAMENT IN HI S LEFT KNEE.

2001 · 18 incidents

September 15, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED ON 9/15/01 IN THE #4 ENTRY (BELT) AT BREAK 128 INTERSECTION ON #7 BELT. FALL WAS 12"HIGH X 25'LONG X 25'WIDE. FALL OCCURRED ON BELT LINE. NO EQUIPMENT OR PE RSONNEL WERE INVOLVED AND THERE WERE NO INJURIES. THE AREA HAD BEEN BOLTED WITH 6'TENSION REBAR AND 9'CABLE BOLTS.

September 13, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 9-13-01 IN THE #3 ENTRY (NEUTRAL AT BREAK #121 INTERSECTION. FALL WAS 6' HIGH X 25' LONG X 25' WIDE. NO EQUIPMENT OR PERSONNEL WERE INVOLVED AND TH ERE WERE NO INJURIES. THE AREA HAD BEEN BOLTED WITH 6' TENSION REBAR AND 9' CABLE BOLTS.

September 10, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 9-10-01 IN THE #5 ENTRY (INTAKE) AT BREAK 82 INTERSECTION. FALL WAS 4' HIGH X 17' WIDE X 30' LONG. NO EQUIPMENT OR PERSONNEL WERE INVOLVED AND THER E WERE N9O INJURIES. THE AREA HAD BEEN BOLTED WITHE 72" RESIN BOLTS.

August 23, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 8-23-01 IN THE #7 ENTRY RETURN AT BREAK 61. FALL WAS APPROXIMATELY 5' HIGH X 17' WIDEX 30' LONG. NO ELQUIPMENT OR PERSONNEL WERE INVOLVED AND THERE WERE NO INJURIES. THE AREA HAD BEEN BOLTED WITH48" RESIN BOLTS.

August 16, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 8/16/01 IN THE #4 ENTRY (NEUTRAL) AT BREAK 94. FALL WAS APPROXIMATELY 10'TO 12'HIGH IN CENTER. NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION WAS NO T INTERRUPTED. THE AREA HAD BEEN BOLTED WITH 7' FULLY GROUTED RODS WITH PIZZA PAUS AS SUPPLEMENTAL SUPPORT FOR DRAW ROCK. FALL OCCURRED ON BELT AND TRACK.

August 10, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #3 HEADING AT BREAK 7 OF PANEL 11 DURING RETREAT MINING ACTIVITIES. FALL WAS 7 1/2 FEET HIGH IN THE #2 LIFT ON THE PILLAR LINE AND CAUGHT THE CONTINU OUS MINER. NO INJURIES, ROOF BOLTED W/6' TORQUE TENSION FULLY GROUTED BOLTS.

August 7, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 8/7/01 IN THE #2 ENTRY (NEUTRAL) AT BREAK 123. FALL WAS APPROXIMATELY 6'HIGH X 18'WIDE X 20'LONG (INTERSECTION). NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION WAS NOT INTERRUPTED. THE AREA HAD BEEN BOLTED WITH 6' REBAR TENSION BOLTS.

August 6, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 8-6-01 IN THE #2 ENTRY (NEUTRAL) AT #125 BREAK. FALL WAS APPROX. 18' W X 20' L X 6' H (INTERSECTION). NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION WAS NOT INTERRUPTED. THE AREA HAD BEEN BOLTED WITH 6' REBAR TENSION BOLTS.

August 2, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 8-2-01 IN THE #5 HEADOING IN TAKE AT #120 BREAK. FALL WAS APPROX. 18' WIDES 20' LONG X 5' HIGH INTERSECTION. NO INJURIES NO EQUIPMENT CAUGHT VENTIL ATION WAS NOT INTERRUPTED. THE AREA HAD BEEN BOLTED WITH 6' TENSION REBAR BOLTS.

August 1, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 8-1-01 IN THE #1 HEADING (RETURN) AT BREAK #121. FALL WAS APPROX 18' WIDE BY 20' LONG BY 10' HIGH. NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION WAS NOT INTERRUPTED. THE AREA HAD BEEN BOLTED WITH 6' TENSION REBAR BOLTS AND CABLE BOLTS IN THE INTERSECTION.

August 1, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNENTERNTIONAL ROOF FALL WAS DISCOVERED ON 8-1-01 IN THE #6 HEADING INTAKE AT BACK 12. FALL WAS APPROX. 6' THICKER 20' LONGX 18' WIDE INTERSECTION. NO INJURIES, NO EQUPMENT CAUGHT, VENTILAT ION WAS NOT INTERRUPTED. THE AREA HAD BEEN BOLTED WITH 6' TENSION REBAR BOLTS.

June 16, 2001 KY · Coal section foreman, bullgang foreman, labor foreman, leadman, shift boss STRIKING OR BUMPING
Consol Of Kentucky Inc · Struck against stationary object

EE STATED THAT HE INJURED HIS NECK WHEN HE STRUCK A ROOF BOLT AS HE WAS WALKING UP BELT ENTRY ONT HE SECTION. EE SUSTAINED A SPRAIN TO HIS NECK.

June 1, 2001 KY · Coal electrician, lineman HANDLING OF MATERIALS
Consol Of Kentucky Inc · Caught in, under or between a moving and a stationary object

EE STATED HE WAS AT MINE FAN HOUSE CHECKING BEARING ON FAN MOTOR FAN WAS OFF, WAS PULLING ON FANBELTS TO MAKE SHAFT TURN SO A DETERMINATION COULD BE MADE ON WHICH BEARING WAS BAD DURING THIS PROCESS EE'S LEFT THUMB GOT CAUGHT BETWEEN BELT PULLEY. EE SUSTAINED FRACTURE TO TIP OF THUMB

March 28, 2001 KY · Coal electrician, lineman SLIP OR FALL OF PERSON
Consol Of Kentucky Inc · Over-exertion (Not Elsewhere Classified)

EE STATED WHILE USING SLATE BAR TO PRY CONVEYOR REDUCER OFF #4 MBC, SLATE BAR SLIPPED, CAUSING HIM TO STUMBLE ALLHIS WEIGHT SHIFTED TOHIS RIGHT ANKLE, EE SUSTAINED RIGHT LATERIAL LIGAMENT DAMA GE TO HIS ANKLE.

March 28, 2001 KY · Coal roof bolter, rock bolter, pinner, mobile roof support operator (mrs) FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Struck by falling object

EMPLOYEE WAS ASSISTING MECHANIC IN CHANGING OUT ELECTRIC PUMP MOTOR ON TWIN HEAD FLETCHER ROOF BOLTER, LEFT HAND WAS RESTING ON ROOF BOLTER WHEN A PIECE OF ROCK FELL FROM THE ROOF STRIKING EMP LOYEE ON HIS LEFT HAND. EMPLOYEE SUSTAINED LACERATIONS AND FRACTURES TO HIS LEFT HAND, EMPLOYEE WAS WEARING METACARPAL GLOVES AT THE TIME OF THE ACCIDENT.

March 10, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED IN THE CROSSCUT AT #87 BREAK BETWEEN THE #3 AND #4 ENTRY. FALL WAS APPROX 25'L X 18'W X 5-6'H. NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION WAS NOT I NTERUPTED. THE AREA HAD BEEN SUPPORTED WITH 5' FULLY GROUTED RESIN BOLTS. FALL WILL NOT BE CLEANED UP.

January 22, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 1-22-01 IN THE #7 ENTRY(RETURN) AT #86 BREAK. FALL WAS APPROX. 20' W X 20' L X 6'-7'H(INTERSECTION). NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION WAS NOT INTERUPTED. THE AREA HAD BEEN BOLTED WITH 5' FULLY GROUTED RESIN BOLTS.

January 13, 2001 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROCKFALL OCCURRED ON 1-13-01 IN THE #4 ENTRY AT #87 BREAK. FALL WAS APPROXIMATELY 60'L X 45'W X 6-8'H. NO INJURIES, #3 MOBIL BRIDGE WAS CAUGHT, VENTILATION WAS NOT INTERUPTED. THE AREA HAD BEEN BOLTED WITH 5' FULLY GROUTED RESIN BOLTS. FALL WILL BE CLEANED UP.

2000 · 4 incidents

October 4, 2000 KY · Coal electrician, lineman FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Struck by falling object

EE WAS CHANGIN OIL FILTERS ON CONT MINER WHEN A PIECE OF DRAW ROCK FELL STRIKING EE ON RIGHT HSOULDER.EE SUSTAINED FRACTURED RIBS (3) BRUISHED RIGHT SHOULDER

August 11, 2000 KY · Coal electrician, lineman FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Struck by falling object

EE WAS PREPARING TO PUT HYDRAULIC OIL IN CONTINUOUS MINER WHEN A PIECE OF ROCK FELL FROM ROOF, STRIKING EE ON HIS RIGHT SHOULDER. EE SUSTAINED A FRACTURE TO HIS RIGHT SHOULDER BLADE.

August 1, 2000 KY · Coal beltman, conveyor man, conveyor belt worker, mobile bridge carrierman, feeder operator, conveyor rider HANDLING OF MATERIALS
Consol Of Kentucky Inc · Over-exertion (Not Elsewhere Classified)

EMPLOYEE WAS HELPING MAKE BELT SPLICE ON #1 BELTWHEN HE EXPERIENCED LOWER BACK PAIN. FIRST SHIFTMISSED DUE TO THIS INCIDENT WAS 8/27/00.

April 5, 2000 KY · Coal FALL OF ROOF OR BACK
Consol Of Kentucky Inc · Accident type, without injuries

AN UNINTENTIONAL ROOF FALL OCCURRED AT BELT PORTAL, A SECTION OF HIGHWALL BECAME DISLODGED FALLING ON BELT PORTAL CANOPY AND MAIN LINE BELT. NO INJURIES, BELT LINE WAS CAUGHT.