Case study · MSHA Record #220120800014

Bull Gang Foreman fatality

March 10, 2012 at 6:15 PM
Kingston No. 2 · Kingston Mining, Inc. · Fayette County, WV
Investigator narrative
There were no witnesses to the event. Victim was found near a rib that had rolled and was not responsive. When found, crew members responded & performed CPR & transported the injured to the surface. The rib portion near the victim was approximately 32" wide - 82" long - and 0-8" in thickness.
Record details
Classification
FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
Accident type
Struck by falling object
Activity at time
Continuous Miner
Subunit / location
UNDERGROUND
Underground location
FACE
Mining method
Continuous Mining
Source of injury
CAVING ROCK,COAL,ORE,WSTE
Nature of injury
CRUSHING
Body part affected
HEAD,NEC
Total mining experience
10 years
Experience at this mine
8 years
Experience in this job
3 years
Mine type
Underground
Sector
Coal
Similar incidents in MSHA records · same classification: FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
  • February 28, 2025 · Marfork Coal Company, LLC · WV · Bull Gang Foreman

    EE had been jack hammering to set a water trap for seals and traded off with coworker to take a break went over to rib sat down when rib roll 68"L x 24" W x 8" T came off at spad #3002/7483 on EE striking EE in the chest and abdomen area.

  • January 29, 2025 · Lexington Coal Company, LLC · WV · Drill Operator

    The employee was drilling a test hole in the surface pit floor to see if the rider coal seam was under the seam they were taking. Due to the freezing and thawing of the highwall a large chunk of rock approximately 4'x2'x3' came down striking the enclosed cab of the mobile drill, ripping the cab off and striking the…

  • August 22, 2024 · Onyx Corporation · MA · Rotary Bucket Excavator Operator