THE VICTIM WAS OPERATING AN AERIAL BOOM TRUCK INSIDE THE BUCKET TO DISMANTLE A SHOP BUILDING. THE VICTIM & TWO OTHER EMPLOYEES WERE USING THE BOOM OF THE BUCKET TRUCK TO LIFT UP WOODEN 4X6 POST. THE POST WAS BURIED IN THE GROUND WITH CONCRETE. WHILE LIFTING THE POST, THE VICTIM WAS THROWN OUT OF THE BUCKET WHEN THE POST SUDDENLY RELEASED FROM THE GROUND.
Charles Collins controller
MSHA controller ID: C14616
Watch this controller
Email me when a new MSHA incident is filed at any mine Charles Collins controls.
- Fatalities
- 3
- Total incidents
- 62
- Mines on record
- 10
- Years on record
- 2000–2014
Compliance record
MSHA citations since 2000
1,465
citations
506
significant & substantial
$569,636
proposed penalties
$193,262
paid to date
Source: MSHA violations data, updated weekly.
Top causes
- MACHINERY 2 fatalities · 5 non-fatal
- ELECTRICAL 1 fatality · 1 non-fatal
- HANDLING OF MATERIALS 21 non-fatal
- FALL OF ROOF OR BACK 12 non-fatal
- NO VALUE FOUND 5 non-fatal
- SLIP OR FALL OF PERSON 4 non-fatal
Incident timeline
2014
3
2013
1
2009
1
2004
1 (1f)
2003
12 (1f)
2002
12 (1f)
2001
11
2000
21
Operators under this controller
Mines on record
- No 1 KY
- Highwall Miner #1 VA
- Highwall Miner #2 AL
- P-9A Red Bird KY
- Calvary No. 80 KY
- #4 KY
- Rebco Coal #2 KY
- Copeland Mine KY
- Calvary No 81 KY
- #1 KY
Fatalities under this controller
3 recorded
February 3, 2004
KY · Coal
belt foreman, maintenance foreman, maintenance supervisor
Fatality · MACHINERY
Calvary Coal Co. Inc
· Fall from machine
Calvary Coal Co. Inc
· Fall from machine
THE VICTIM WAS OPERATING A BOOM TRUCK, ASSISTING IN THE TAKING DOWN OF A LINE DROP TOWER FROM AN ELECTIRCAL SUBSTATION. THE WINCH ROPE BROKE CAUSING HIM TO BE THROWN FROM THE BUCKET OF THE BOO M TRUCK. HE FELL APPROXIMATELY 25 FEET. (THIS WAS NOT AN ELECTRICAL ACCIDENT. THE SUBSTATION WAS NOT IN SERVICE.)
Calvary Coal Co. Inc
· Contact with electrical current
THE ELECTRICIAN WAS WORKING ON A GROUNDED SHUTTLE CAR CABLE AND RECEIVED FLASH BURNS WHEN A SHORT CIRCUIT OCCURED AT THE FEMALE RECEPLACLE ON THE ELECTRICAL POWER CENTER.